13.6 BNW-51 OUTLINE DRAWING
220±1
210±1
198±1
ALARM
C
Bridge Navigational Watch Alarm System
A
1
B
C
AUTOPOWER ERROR ALARM TIMER
Processor Unit
BNW-51
2
3 4 5
165±1
95±1
4-
Ø
4.2
GND
10
DISPLAY
IN/OUT
24V
4
RXD
SLD
TXD
21 3
GND
12V
RES
RES
12V
RES2 RES1
LOW
5 6
LOW
7 8 9
VIS
GND
AUD
ALARM
11
VIS+AUD
131 2
GND
GND
24V
24V
24V
ALARM ALARM
1715
A
14
B
16 18
D
E
6 7 8
EMERG
39
ALARM
24V
24
GND
GND
24V
GND
24V
ALARM ALARM
2119
D
20
E
22 23
GND
GND
24V
ALARM
F
25
G
26 27
NMEA
TXD
TXD-
33
OUT-
OUT+
INP-
INP+
TXD+
ALARM REMOT
FAIL
28 29
TRAK
30 31 32
RXD-
SLD
RXD+
INP-
INP+
NMEA RES3
RXD
3634 35
PULS
3837
INP-
INP+
40
EXT
70±1
AC FUSE(2A)
110/220VAC
1
INTERFACE
14
GND
9
DC FUSE(5A)
13
POWER 12V DC
27